Effectiveness of traditional, artificial intelligence-assisted, and virtual reality training modalities for focused cardiac ultrasound skill acquisition: a randomised controlled study

Effectiveness of traditional, artificial intelligence-assisted, and virtual reality training modalities for focused cardiac ultrasound skill acquisition: a randomised controlled study

21 November 2025

Yie Hui Lau, Sanchalika Acharyya, Cadence Wei Lin Wee, Huiying Xu, Rafael Pulido Saclolo, Kelly Cao & Wee Kim Fong

Background

Focused cardiac ultrasound (FCU) is increasingly used as an extension of physical examination to aid diagnosis and clinical decision-making.

Emerging educational technologies such as artificial intelligence (AI)-enabled ultrasound devices and virtual reality (VR) simulators offer novel, cost-effective and self-directed approaches for FCU skill acquisition training.

Prior studies suggest that VR-based training may be non-inferior to traditional teaching, while AI offers real-time feedback to enhance learning.

Objective

This study aimed to evaluate the effectiveness and non-inferiority of AI and VR-assisted training compared to Traditional in-person instruction in achieving competency in FCU image acquisition.

Secondary outcomes included time to acquire an optimal apical 4 chamber (A4C) view and self-reported confidence in image acquisition, assessed immediately post-training and at 3-month follow up.

Methods

In this single-blind, randomized controlled pilot trial, 66 local medical students with no prior FCU experience were randomised into 3 arms: (1) AI-enabled ultrasound training using the Kosmos system, (2) VR-based stimulator (Vimedix), and (3) Traditional instructor-led teaching.

All sessions were 60 min long. Image acquisition of 5 standard FCU views was assessed by blinded evaluators using the Rapid Assessment of Competency in Echocardiography (RACE) score at both time points.

Results

Two participants were lost to follow-up (one each from the AI and VR groups). In the first assessment, the Traditional group achieved the highest mean RACE score (15.77), followed by AI (13.39) and VR (13.23).

Non-inferiority testing confirmed that both AI (95% CI −∞ to 3.60; p < 0.001) and VR (95% CI −∞ to 3.58; p < 0.001) methods were non-inferior to Traditional instruction.

The AI group achieved the shortest mean time to acquire an optimal A4C view (158 ± 99.1 s), followed by the VR (189 ± 94.7 s), and traditional (199 ± 115.1 s), though differences were not statistically significant (p = 0.591).

Confidence levels were initially highest in the Traditional group, while the VR group showed higher confidence at 3-month follow-up, particularly in parasternal long-axis view acquisition.

Echocardiography performance changes across training groups

Conclusion

Peyton’s four-step method improves overall psychomotor skill acquisition for POCUS. Peyton’s four-step method specifically improved psychomotor skills in the immediate skill acquisition phase and the delayed skill acquisition phase. The benefit of Peyton’s four-step method was more prominent in POCUS applications with higher complexity.

No Comments

Sorry, the comment form is closed at this time.